11 research outputs found

    Power fuzzy adaptive control for wind turbine

    Get PDF
    In recent years, wind energy has become one of the most promising renewable energy sources. The doubly-fed induction generator (DFIG) is currently the most common type of generator used in wind farms. This paper describes an approach for the independent control of the active and reactive power of the variable-speed DFIG. This paper deals with the control of the active and reactive powers in a DFIG designed for a wind system. The simulation model including a 7 KW - DFIG driven by a wind turbine, a PWM inverter and the proposed control strategy are developed and implemented using Matlab Simulink

    Modeling, Simulation and Control of a Doubly-Fed Induction Generator for Wind Energy, Conversion Systems

    Get PDF
    © 2020 The Author(s). This work is licensed under a Creative Commons Attribution-ShareAlike 4.0 International License (https://creativecommons.org/licenses/by-sa/4.0/).In recent years, wind energy has become one of the most promising renewable energy sources. Various wind turbine concepts with different generator topologies have been developed to convert this abundant energy into electric power. The doubly-fed induction generator (DFIG) is currently the most common type of generator used in wind farms. Usually the DFIG generator is a wound rotor induction machine, where the stator circuit is directly connected to grid while the rotor’s winding is connected to the grid via a three-phase converter. This paper describes an approach for the independent control of the active and reactive powers of the variable-speed DFIG. The simulation model including a 1.5 MW-DFIG driven by a wind turbine, a PWM back-to-back inverter and the proposed control strategy are developed and implemented using MATLAB/Simulink/SimPowerSystems environment.Peer reviewedFinal Published versio

    Mitigation of Harmonics and Inter-Harmonics with LVRT and HVRT Enhancement in Grid-Connected Wind Energy Systems Using Genetic Algorithm-Optimized PWM and Fuzzy Adaptive PID Control

    Get PDF
    © 2021 Author(s). This is the accepted manuscript version of an article which has been published in final form at https://doi.org/10.1063/5.0015579The growing installed wind capacity over the last decade has led many energy regulators to define specific grid codes for wind energy generation systems connecting to the electricity grid. These requirements impose strict laws regarding the Low Voltage Ride Though (LVRT) and High Voltage Ride Though (HVRT) capabilities of wind turbines during voltage disturbances. The main aim of this paper is to propose LVRT and HVRT strategies that allow wind systems to remain connected during severe grid voltage disturbances. Power quality issues associated with harmonics and inter-harmonics are also discussed and a control scheme for the grid-side converter is proposed to make the Wind Energy Conversion System insensitive to external disturbances and parametric variations. The Selective Harmonic Elimination Pulse Width Modulation technique based on Genetic Algorithm optimization is employed to overcome over-modulation problems, reduce the amplitudes of harmonics, and thus reduce the Total Harmonic Distortion in the current and voltage waveforms. Furthermore, to compensate for the fluctuations of the wind speed due to turbulence at the blades of the turbine, a fuzzy Proportional-Integral-Derivative controller with adaptive gains is proposed to control the converter on the generator side.Peer reviewedFinal Accepted Versio

    Impact of the Integration of a STATCOM Controlled by LQG/H2 Regulator in an Energy System

    Get PDF
    © The Author(s); licensee IIETA, Edmonton, Canada. This is an open access article distributed under the terms of the Creative Commons Attribution License (CC BY), https://creativecommons.org/licenses/by/4.0/Nowadays, the reactive power consumption is becoming a serious problem for electricity network management. To overcome this problem, several solutions are proposed in the literature. In the present study, the static reactive power compensator (STATCOM) solution is used to keep the network voltage within its rated range. The STATCOM is modeled in the axes of Park reference frame and is driven controlled by a SVPWM strategy. Its control scheme is based on a multivariable Linear Quadratic Gaussian (LQG/H2) controller, which has the advantage of being applied to systems whose condition is not measured. Simulations are performed using the MATLAB/SIMULINK software. Results are presented, compared and discussed.Peer reviewe

    Power Quality Enhancement in Electricity Grids with Wind Energy Using Multicell Converters and Energy Storage

    Get PDF
    In recent years, the wind power industry is experiencing a rapid growth and more wind farms with larger size wind turbines are being connected to the power system. While this contributes to the overall security of electricity supply, large-scale deployment of wind energy into the grid also presents many technical challenges. Most of these challenges are one way or another, related to the variability and intermittent nature of wind and affect the power quality of the distribution grid. Power quality relates to factors that cause variations in the voltage level and frequency as well as distortion in the voltage and current waveforms due to wind variability which produces both harmonics and inter-harmonics. The main motivation behind work is to propose a new topology of the static AC/DC/AC multicell converter to improve the power quality in grid-connected wind energy conversion systems. Serial switching cells have the ability to achieve a high power with lower-size components and improve the voltage waveforms at the input and output of the converter by increasing the number of cells. Furthermore, a battery energy storage system is included and a power management strategy is designed to ensure the continuity of power supply and consequently the autonomy of the proposed system. The simulation results are presented for a 149.2 kW wind turbine induction generator system and the results obtained demonstrate the reduced harmonics, improved transient response, and reference tracking of the voltage output of the wind energy conversion system.Peer reviewedFinal Accepted Versio

    Voltage Profile and Power Quality Improvement Using Multicell Dynamic Voltage Restorer

    Get PDF
    This work is licensed under a Creative Commons Attribution-Share Alike 4.0 International License.Multi-level converter topologies are increasingly being used in various applications due to their high power, high voltage, and low harmonic levels in the output waveforms. These converter topologies produce different output voltage levels and have a highly modular structure. This paper proposes the design of a dynamic voltage restorer (DVR) based on multilevel topology to enhance the voltage profile and improve the power quality in the network. The DVR is an effective, fast-acting device which detects voltage sags and swells in a transmission line and inject a compensating voltage through a boost transformer. A simulation study is carried out under MATLAB/Simulate to demonstrate the performance of the proposed DVR circuit. The simulation results show improved transient response and enhanced power quality in the transmission network.Peer reviewe

    ANFIS control of a shunt active filter based with a five-level NPC inverter to improve power quality

    Get PDF
    © 2021 The Author(s). This is an open access article under the CC BY-SA license (https://creativecommons.org/licenses/by-sa/4.0/).This paper addresses the problem of power quality, and the degradation of the current waveform in the distribution network which results directly from the proliferation of the nonlinear loads. We propose to use a five-level Neutral Point Clamped (NPC) inverter topology for the implementation of the shunt active filter (SAPF). The aim of the SAPF is to inject harmonic currents in phase opposition at the connection point. The identification of harmonics is based on the pq method. A neuro-fuzzy controller based on ANFIS (Adaptive Neuro Fuzzy Inference System) is designed for the SAPF. The simulation study is carried out using MATLAB/Simulink and the results show a significant improvement in the quality of energy and a reduction in Total Harmonic Distortion (THD) in accordance with IEC standard, IEEE-519, IEC 61000, EN 50160.Peer reviewe

    Wind Turbine Active Fault Tolerant Control Based on Backstepping Active Disturbance Rejection Control and a Neurofuzzy Detector

    Get PDF
    © 2023 The Author(s). Licensee MDPI, Basel, Switzerland. This is an open access article distributed under the terms of the Creative Commons Attribution License (CC BY), https://creativecommons.org/licenses/by/4.0/Wind energy conversion systems have become an important part of renewable energy history due to their accessibility and cost-effectiveness. Offshore wind farms are seen as the future of wind energy, but they can be very expensive to maintain if faults occur. To achieve a reliable and consistent performance, modern wind turbines require advanced fault detection and diagnosis methods. The current research introduces a proposed active fault-tolerant control (AFTC) system that uses backstepping active disturbance rejection theory (BADRC) and an adaptive neurofuzzy system (ANFIS) detector in combination with principal component analysis (PCA) to compensate for system disturbances and maintain performance even when a generator actuator fault occurs. The simulation outcomes demonstrate that the suggested method successfully addresses the actuator generator torque failure problem by isolating the faulty actuator, providing a reliable and robust solution to prevent further damage. The neurofuzzy detector demonstrates outstanding performance in detecting false data in torque, achieving a precision of 90.20% for real data and 100%, for false data. With a recall of 100%, no false negatives were observed. The overall accuracy of 95.10% highlights the detector’s ability to reliably classify data as true or false. These findings underscore the robustness of the detector in detecting false data, ensuring the accuracy and reliability of the application presented. Overall, the study concludes that BADRC and ANFIS detection and isolation can improve the reliability of offshore wind farms and address the issue of actuator generator torque failure.Peer reviewe

    Multivariable control of a grid-connected wind energy conversion system with power quality enhancement

    Get PDF
    This document is the Accepted Manuscript version of the following article: Kaddour Fouad, Houari Merabet Boulouiha, Ahmed Allali, Ali Taibi, and Mouloud Denai, ‘Multivariable control of a grid-connected wind energy conversion system with power quality enhancement’, Energy Systems, Vol. 9 (1): 25-57, February 2018. The final publication is available at Springer via: https://doi.org/10.1007/s12667-016-0223-7This paper proposes the design of a multivariable robust control strategy for a variable-speed WECS based on a SCIG. Optimal speed control of the SCIG is achieved by a conventional PI controller combined with a MPPT strategy. DTC-SVM technique based on a simple Clarke transformation is used to control the generator-side three-level converter in the variable speed WECS. The flow of real and reactive power between the inverter and the grid is controlled via the grid real and reactive currents and the DC link voltage using multivariable H∞ control. The overall WECS and control scheme are developed in Matlab/Simulink and the performance of the proposed control strategy is evaluated via a set of simulation scenarios replicating various operating conditions of the WECS such as variable wind speed and asymmetric single grid faults. The power quality of the WECS system under H∞ control control approach is assessed and the results show a significant improvement in the total harmonic distorsion as compared to that achieved with a classical PI control.Peer reviewedFinal Accepted Versio

    A four-line active shunt filter to enhance the power quality in a microgrid

    No full text
    In recent years, power quality has become a major concern for electric network managers. Active filtering control schemes ensure improved power quality of the electric network and are able to maintain a desired voltage level at the point of connection, regardless of the current absorbed by nonlinear loads. Harmonics can cause vibrations, equipment distortion, losses and sweatiness in transformers. The main objective of this work is to enhance the quality of energy in a microgrid consisting of 100 kW photovoltaic (PV) system and a 50 kW battery storage connected to nonlinear and unbalanced loads. This paper proposes a the four-arm parallel active filter with a on Proportional-Integral (PI) controller to mitigate the harmonic problems in a microgrid. In addition, an algorithm has been designed to eliminate the neutral current. The identification function is one of the most particular approach for extracting harmonics, it involves providing a current reference imposed by the active filter in order to carry out the filtering operation. Both the performance and the quality of the current harmonic compensation's depend strongly on the strategy adopted for the generating the current reference. In this work, the instantaneous power strategy p-q is chosen outstanding the simplicity and effectiveness in implementation. The proposed control strategy has been tested under simulations and the results have shown good tracking of the references and a significant reduction in the Total Harmonic Distorsion (THD) level under highly unbalanced conditions of the nonlinear loads. The current THD is reduced from 43.64 before filtering to 3.74% after the application of the four-arm filter, following the recommendations of IEEE-519 standard (THD less than 5%)
    corecore